6 Hydraulics Diagnostics
Response
Remedy
Continue program
300 854
Explanation
Response
Remedy
Continue program
310 505
Explanation
6-196
Under certain circumstances it can be switched over across the entire channel
via MD.
NC not ready.
Mode group not ready.
NC stopped in response to alarm.
NC start disable.
The NC switches to follow-up mode.
Alarm display.
Interface signals are set.
The newly calculated data must be saved (soft key: SAVE).
The new parameter settings become operative when the system is next booted!
Switch control system OFF and ON again.
Axis %1, drive %2 signal number var. signaling function invalid
%1 = NC axis number
%2 = drive number
The signal number for output of the appropriate signaling function is illegal. The
signal number range is between 0 and 29.
Alarm display
Interface signals are set
Enter the correct signal number.
Alarm display with cause of the alarm disappears. No further operator action
required.
Axis %1, drive %2 meas. circuit error abs. track, code %3
%1 = NC axis number
%2 = drive number
%3 = detailed error code
Absolute encoder (EQN 1325)
Monitoring of encoder hardware and EnDat or SSI interface.
-
Error in SSI encoder parameters (MD 5028)
-
SSI encoder: Fault in 24 V voltage supply
-
SSI encoder: Break in data or clock pulse cable
More precise diagnosis via error code MD 5023: ENC_ABS_DIAGNOSIS_MO-
TOR (diagnosis of absolute track in motor meas. circuit):
Bit no.
Meaning
Bit 0
Lighting failed
Bit 1
Signal amplitude too small
Bit 2
Faulty code connection
Bit 3
overvoltage
Bit 4
Undervoltage
Bit 5
Overcurrent
Bit 6
Battery change necessary
Bit 7
CRC error (evaluate bit 13 as well)
SINUMERIK 840D/SIMODRIVE 611 digital, HLA Module (FBHLA) - 10.03 Edition
Note
See 1)
Siemens AG, 2003. All rights reserved