Timing of the GPI signal
Player A
Player B
Recorder
GPI signal
PGM OUT
signal

Turning a Downstream Key On and Off

GPI signal
The timing of the GPI signal from the editing control unit is as follows.
VCRs start IN point
3 frames
Background bus image
Preroll
A-roll period
Timing of GPI signal in A/B roll editing
If in page 1 of the setup menu you have set F3(PORTS) to "PVE-500" or
"GPI" then you can turn a downstream key on and off using a GPI signal
input to the T2 connector on the DFS-700/700P.
As shown below, the downstream key is turned alternately on and off at
the falling edge of the GPI signal.
3 frames
DSK ON
Turning a downstream key on and off — GPI signal timing
Effect start point
Foreground bus
image
Execution of
effect (transition)
B-roll period
3 frames
DSK OFF
Chapter 5 Control From Editing Control Units
OUT point
VCRs stop
Postroll