hit counter script

Warning Messages - Sony DFS-700 Operating Instructions Manual

Sony dfs-700/700p dme switcher operating instructions
Hide thumbs Also See for DFS-700:
Table of Contents

Advertisement

Warning Messages

Warning message list
Display
011 FAN STOP!!
->Turn OFF Power
012 Power Unit Error
->Turn OFF Power
021 Reference Signal Error
->
022 Self Diagnostic Error xxxx/xxxx
-> Check on Maintenance menu
023 Software Version Mismatch
-> Load the latest S/W
031 Data Backup Error
->
A-2
Appendixes
The following warning messages are displayed.
Meaning
The processor detected that the power
supply fan is stopped.
There is trouble with the power supply.
Video sync signals are not being sent
correctly from the main unit to the
control panel.
An error was detected during self
diagnostics when the system was
powered on. (xxxx/xxxx indicates the
error status.)
The processor and control panel
software versions are different.
User program, setup or other data could
not be written to backup memory.
What to do
Turn off the power and check the power
supply fan. If this does not solve the
problem, contact a Sony service
representative.
Turn off the power and check the power
supply. If this does not solve the
problem, contact a Sony service
representative.
Check the cable connection.
Contact your vendor or a Sony service
representative.
Contact your vendor or a Sony service
representative.
Contact your vendor or a Sony service
representative.