Detailed Description
2.9 Mode group, channel, program operation, reset response (K1)
DB21, ...
DBX7.7
Reset
Edge evaluation: no
Signal state 1 or
The channel is reset. The initial settings are set (e.g. G functions).
edge change
The alarms for the channel are cleared if they are not POWER ON alarms.
0 → 1
The reset signal must be issued by the PLC (e.g., using a logic operation with the reset key on the
MCP). The signal is only evaluated by the selected channel.
The program status changes to "Aborted", and the channel status changes to "Channel status
reset".
Signal state 0 or
No effect.
edge change
1 → 0
Corresponds to ....
DB11, ... DBX0.7 (mode group reset)
DB21, ... DBX35.7 (channel status reset)
DB21, ...
DBX31.0 - DBX31.2
REPOS mode (REPOSPATHMODE)
Edge evaluation: no
REPOS mode specified by HMI:
Bit:2 1 0
Corresponds to ....
DB21, ...DBX25.0 - DBX25.2 (REPOS mode (REPOSPATHMODE))
DB31, ... DBX10.0 (REPOSDELAY)
DB21, ...
DBX31.4
REPOS mode change (REPOSMODEEDGE)
Edge evaluation: yes
Signal state 1 or
The REPOS mode has changed:
edge change
DB21, ... DBX31.0 - DBX31.2 (REPOS mode (REPOSPATHMODE))
0 → 1
Signal state 0 or
REPOS mode has not changed.
edge change
1 → 0
Corresponds to ....
DB21, ... DBX31.0 - DBX31.2 (REPOS mode (REPOSPATHMODE))
DB21, ... DBX319.0 (REPOSMODEEDGEACKN)
DB21, ...DBX31.0 - DBX31.2 (REPOS mode (REPOSPATHMODE))
2-96
Signal(s) updated: cyclic
Signal(s) updated: cyclic
0 0 0 = 0: no REPOS mode active
0 0 1 = 1: Re-approach to block start RMB
0 1 0 = 2: Re-approach to interruption point RMI
0 1 1 = 3: Re-approach to block end point RME
1 0 0 = 4: Re-approach to nearest path point RMN
Signal(s) updated: cyclic
NC/PLC Interface Signals (Z1)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0