Detailed Description
2.1 Various interface signals and functions (A2)
DB19
DBX16.7
Active or passive file system
Edge evaluation: no
Signal state 1 or
Passive file system
edge change 0 → 1
Signal state 0 or
Active file system
edge change 1 → 0
Application
With HMI Advanced always 1
example(s)
DB19
DBX17.0 - DBX17.7
PLC line offset in the user control file
Edge evaluation: no
Description
This byte for controlling file transfer via the hard disk defines the line of the user control file in which
the control file to be transferred is located.
Application
Valid for HMI Advanced, with reference to DB19.DBB13
example(s)
Dependent on:
DB19.DBX14.7=0 → Act. FS: PLC line offset in a standard control file
DB19.DBX14.7=1 → Pas. FS: PLC line offset in a user control file
DB19
DBX44.0
Mode change disable
Edge evaluation: no
Signal state 1 or
Mode change disable active
edge change 0 → 1
Signal state 0 or
Mode change disable inactive
edge change 1 → 0
DB19
DBX45.0
FC9 Out: Active
Edge evaluation: no
DB19
DBX45.1
FC9 Out: Done
Edge evaluation: no
2-16
Signal(s) updated: cyclic
Signal(s) updated: cyclic
Signal(s) updated: cyclic
Signal(s) updated: cyclic
Signal(s) updated: cyclic
NC/PLC Interface Signals (Z1)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0