Siemens SINUMERIK 840D sl Function Manual page 177

Sinumerik integrate amb, amc, amm
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

03/2013
Fig. 3-61: PLC trace: Adding variables
Note
By default, PLC addresses are restricted to the address range of the smallest
PLC.
To remove this restriction if you are using a more powerful PLC and want to use
the addresses in SINUMERIK Integrate, increase the related values in the trigger
DB (DB239 in SINUMERIK Integrate Standard) in DW8 for inputs, DW10 for
outputs, DW12 for flags, DW14 for timers, and DW16 for counters, to the
available address ranges. Restarting the PC that holds the client is necessary.
Warning
Using the trigger DB with an increased address range can cause the PLC to stop
when you use the higher addresses in SINUMERIK Integrate configurations, and
this address range is not really available in the connected PLC.
Function
Name
Remaining memory
for the PLC trace
configuration
Remaining memory
for the PLC trace
data
© Siemens AG 2006-2013 All Rights Reserved
SINUMERIK Integrate AMB, AMC, AMM, Function Manual (FH) - 03/2013
Description
Name of the PLC trace: Can be entered by the user.
If the field remains empty or is cleared,
SINUMERIK Integrate enters the name: Execute and
upload PLC trace.
Displays the remaining memory in the DB for
addressing variables in the PLC.
Shows the remaining memory in the DB of the PLC
for recording the variables status. The memory
requirement is directly related to the number of
cycles to be recorded.
3 Setting up functions
3.4 Fault Services
Type
DISPLAY
INPUT
(max. 100
characters, all
characters are
permissible)
DISPLAY
DISPLAY