Parameters
CTABTSV
CTABTEV ()
CTABTSP ()
CTABTEP ()
CTABMIN ()
CTABMAX ()
Faxis
Laxis
n, m
degrees
Values and value range
Values of the trailing and leading axis located at the beginning and end of a curve table
CTABTSV, CTABTEV, CTABTSP, CTABTEP
R10=CTABTSV(n, degrees, Faxis).
R10=CTABTEV(n, degrees, Faxis).
R10=CTABTSP(n, degrees, Laxis).
R10=CTABTEP(n, degrees, Laxis).
Value range of curve table of following value CTABTMIN, CTABTMAX
R10=CTABTMIN(n, Faxis).
R10=CTABTMAX(n, Faxis).
R10=CTABTMIN(n, a, b, Faxis, Laxis)
R10=CTABTMAX(n, a, b, Faxis, Laxis)
Note
R parameter assignments in the table definition are reset.
Job planning
Programming Manual, 03/2006 Edition, 6FC5398-2BP10-1BA0
Read the start value of the curve table from a following
axis.
Read the end value of the curve table from a following axis.
Read the start value of the curve table from a leading axis.
Read the end value of the curve table from a leading axis.
Determine the minimum value of a curve table in the complete
area or in a defined interval.
Determine the maximum value of a curve table in the complete
area or in a defined interval.
Following axis
Axis that is programmed via the curve table.
Leading axis
Axis that is programmed with the master value.
Number of curve tables
Curve table numbers can be freely assigned. They are used
exclusively for the unique identification.
Gradient for incline at start or end of the segment in the
curve table
Path traversing behavior
9.3 Curve tables (CTAB)
Trailing value at beginning of curve table
Trailing value at beginning of curve table
Master value at beginning of curve table
Master value at end of curve table
Minimum following value of curve table
over entire interval
Maximum following value of curve table
over entire interval
Minimum following value of curve table in
interval a...b of master value
Maximum following value of curve table
in interval a...b of master value
9-23