01.99
3.3
Parameterizing using the parameterizing and start–up tool SimoCom U
Table 3-3
Information on SimoCom U, continued
Function
Expert list
... displays all of the "SIMODRIVE 611 universal" parameters.
You can individually change any parameter via the expert list. The operator has
no additional support here. This list parameterization should only be used in
exceptional cases.
S
Assign the PC the
... means that the terminal signals are ignored at the terminals and instead, the
master control
drive evaluates signals set by the PC.
This means that the enable signals to traverse the drive can be output from the
PC.
Exception:
The pulse enable (terminal 663) and the controller enable (terminal 65.x) must
be provided, as before, via the input terminals.
This is for safety: You can withdraw these enable signals at any time, using a
switch in order to switch the drive into a no–current condition or shut it down.
Transfer the master
... you then obtain a display of the voltage level available at the terminals
control from the PC
compared to the signals set by the PC.
back to the terminals
The master control is only transferred back to the terminals after
acknowledgement.
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Operator control information
– Call: Menu "Start–up/Additional parameters/Expert list"
– If you open the list, you will additionally obtain the menu, which can also
be reached using the righthand mouse key.
– It is especially interesting that the standard value and value limits for the
actual parameters are displayed in the status line.
– Modified values only become effective after pressing the Enter key or if
another parameter was selected. Values which are inactive have a red
background.
– In the "List" menu, you can select which data should appear in the list:
All, or only the controller data, or only the sub–parameter set 0 or ....
Furthermore, you can search for specific terms with F3 (or list/search
menu), e.g. you can search for "temp" if you wish to change the
temperature warning threshold value.
– Bit–coded values: Go with the cursor to the line and press F4 (or menu,
List/bit values). You then obtain a plain text display of the individual bits
and can select these at a click of the mouse.
3 Parameterizing the Board
Description
3
3-101