Siemens SIMODRIVE 611 universal Function Manual page 257

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

08.99
08.02
Table 5-25
Parameters for configuring the process data, continued
No.
Name
Note:
S
For P0922 > 0, the following is valid:
P0915:17 is pre–assigned at run–up corresponding to the selected standard telegram in
P0922.
A change made to P0915:2 to P0915:16 is overwritten again at the next run–up corre-
sponding to the selected standard telegram.
S
Operating mode not specified ––> possible in every operating mode
S
The following applies for P0922 = 0:
Before SW 4.1 ––> From P0915:5 (assignment for PZD5), process data can be freely con-
figured. This means from P0915:5, the signal ID of the requested signal can be entered.
From SW 4.1 ––> From P0915:2 (assignment for PZD2), process data can be freely con-
figured, i.e. from P0915:2, the signal ID of the required signal can be entered.
P0915:0
P0915:1
P0915:2
...
P0915:16
S
An overview of the control words is available in Chapter 5.6.1.
S
The process data for encoder 2 must be activated via P0879.12.
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Min.
Standard
No significance
PZD1
Configuring not possible (standard setting)
PZD2
Free configuring possible (from SW 4.1, before SW 4.1
from PZD5), i.e. enter the required signal ID
...
PZD16
Free configuring possible,
i.e. enter the required signal ID
5 Communications via PROFIBUS DP
5.6
Net data (PKW and PZD area)
Max.
Units
Effective
5
5-257