7 Fault Handling/Diagnostics
7.3
List of faults and warnings
761
Cause
Remedy
Acknowledgement
Stop response
762
Cause
Remedy
Acknowledgement
Stop response
764
Cause
Remedy
Acknowledgement
Stop response
765
Cause
Remedy
Acknowledgement
Stop response
7-686
P0892 cannot be used with this measuring system
The following settings are permitted (Order No.[MLFB] 6SN1118–.... ):
Incremental measuring systems ( 7 bit ) with sin/cos 1 Vpp without En-
Dat interface (..*NH00–0AA*, ..*NH10–0AA*) : 0
Incremental measuring systems ( 7 bits ) with sin/cos 1 Vpp with EnDat
interface (..*NH00–0AA*, ..*NH10–0AA*) : 0,1,2,3
Incremental measuring systems ( 11 bit ) with sin/cos 1 Vpp
(..*NH01–0AA*, ..*NH11–0AA*) : 0,1,2,3,4
resolver ( 12 bit ) (..*NK00–0AA0 or ..*NJ00–0AA0) : 0,1,2,3
Resolver ( 12 bit ) (..*NK01–0AA0 or ..*NJ01–0AA0) with 12-bit resolu-
tion ( 1011[2]=0 or 1030[2]=0 ) : 0,1,2,3,4,5
Resolver ( 14 bit ) (..*NK01–0AA0 or ..*NJ01–0AA0) with 14 bit resolu-
tion ( 1011[2]=1 or 1030[2]=1 ) : –2,–1,0,1,2,3
Set P0892 (factor, angular encoder pulse number/encoder pulse num-
ber) to a valid value.
POWER ON
STOP II (SRM, SLM) STOP I (ARM)
P0893 cannot be used with this measuring system
For incremental measuring systems with sin/cos 1 Vpp without EnDat
interface and for linear measuring systems with sin/cos 1 Vpp with En-
Dat interface, a zero pulse offset cannot be set via P0893.
Set P0893 (angular encoder zero pulse offset) to 0.
POWER ON
STOP II (SRM, SLM) STOP I (ARM)
Multiple assignment of terminal A or B (P0890)
When selecting 3 in P0890, from drive A or B (setpoint at terminal A
and actual value at terminal B), it was identified, that terminal A or B
were already being used by another drive. Thus, this configuration is
not possible.
Check the configuration of terminals A and B in P0890 and eliminate
multiple assignments of both drives.
POWER ON
STOP II (SRM, SLM) STOP I (ARM)
P0890 and P0891 configure both setpoint inputs
An actual value coupling is switched in (P0891 = 1) for drive B. Simul-
taneously, for the same drive, terminal A or B is parameterized as posi-
tion setpoint input (P0890 = 2 or 3).
Check the configuration of terminals A and B in P0890, compare with
P0891 and eliminate multiple setpoint sources.
POWER ON
STOP II (SRM, SLM) STOP I (ARM)