01.99
04.05
830
PROFIBUS: Illegal configuration received. Reason: \%u
Cause
An illegal configuration frame was received via PROFIBUS. Cyclic data
transfer cannot start.
Reasons:
1 = In the master, more axes are configured than are physically
2 = The number of the axes configured in the master is not equal to
3 = Configuration incomplete (too short) for one of the PPL types
4 = No PPO type detected (only for P875 = 2).
5 = Length calculation different between firmware and option module.
6 = For active data exchange, a new configuration was received with
7 = Configuration contained unknown S7 ID.
19 = More PZD's have been configured than the maximum permissible.
20 = The configurtion contains an unknown special character (only axis
22 = Target offset of slave-to-slave communications access exceeds
28 = Number of slave-to-slave communication IDs differs from the
29 = Setpoint PZDs are not uniformly supplied by the master or slave
30 = The permitted maximum length of the configuration telegram for
Remedy
Check the bus configuring at the master and if required correct.
If required, using P875, activate the option module PROFIBUS-DP,
which are previously configured in the PROFIBUS Master for the num-
ber of axes involved.
Acknowledgement
not required
Stop response
STOP VII
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
present in the power module.
the number axes where the PROFIBUS DP option module is
switched active via P0875. Note: Communications with axis B are
not automatically de-activated even when switching axis B into a
passive state.
(only for vor P875 = 2).
different length.
separators are permitted).
the maximum number of PZDs
number of accesses in the parameterizing telegram.
(drive) publisher.
the option module has been exceeded.
7 Fault Handling/Diagnostics
7.3
List of faults and warnings
7
7-703