12 ERROR CODE LISTS
Error
Details
code
code
Name
Indirect specified 64-
16467
bit data register
(D(n)F) read error
Indirect specified 16-
16468
bit link register (W(n))
read error
Indirect specified 32-
16469
bit link register
(W(n)L) read error
Indirect specified 64-
16470
bit link register
(W(n):F) read error
Indirect specified
16475
SM(SM(n)) read error
Direct specified
Multiple CPU area
device bit specified for
16482
CPU No.1
(U3E0\G10000.0 to)
read error
Direct specified
Multiple CPU area
device bit specified for
16483
CPU No.2
(U3E1\G10000.0 to)
read error
Direct specified
Multiple CPU area
device bit specified for
16484
CPU No.3
(U3E2\G10000.0 to)
read error
Direct specified
Multiple CPU area
device bit specified for
16485
CPU No.4
(U3E3\G10000.0 to)
read error
Indirect specified input
16486
relay (X(n)) read error
Indirect specified
16487
output relay (Y(n))
read error
Indirect specified
16488
internal relay (M(n))
read error
Indirect specified link
16489
relay (B(n)) read error
Annunciator (F(n))
16490
read error
Indirect specified 16-
16516
bit batch input relay
(X(n)) read error
Indirect specified 32-
16517
bit batch input relay
(X(n)) read error
Indirect specified 16-
16518
bit batch output relay
(Y(n)) read error
Indirect specified 32-
16519
bit batch output relay
(Y(n)) read error
Error factor
Description
The indirectly specified device No. is outside
the range or an odd number.
The indirectly specified device No. is outside
the range.
The indirectly specified device No. is outside
the range or an odd number.
The indirectly specified device No. is outside
the range.
Multiple CPU area device number is outside
the range set in the parameter.
Multiple CPU area device number is outside
the range set in the parameter.
The indirectly specified device No. is outside
the range.
The indirectly specified device No. is
outside the range or is not a multiple of 16.
12 - 20
Error Processing
Correct the program so that the indirectly
specified device No. is proper.
Correct the program so that Multiple CPU
area device number is within the range set in
the parameter.
The block processing
in execution is
stopped and the next
block is executed.
Correct the program so that the indirectly
specified device No. is proper.
Corrective Action