11 MECHANICAL SYSTEM PROGRAM

11.3 Device range

The below devices can be used for "Indirect setting" of "Transmission module"
and "Output module" in Mechanical support language.
(1) Bit devices
Table 11.2 Bit devices List
Name
Input relay
Output relay
Internal relay
Link relay
Annunciator
(2) Word devices
Table 11.3 Word devices List
Name
Data register
Link register
Motion register
Remark
An error will occur if the multi-CPU common devices
(for Q172DCPU/Q173DCPU) are set.
Setting range
X0000 to X1FFF
Y0000 to Y1FFF
M0 to M8191
B0000 to B1FFF
F0 to F2047
Setting range
D0 to D8191
W0 to W1FFF
#0 to #12287