12 COMMUNICATION
12.1.2 Hub Connection
The Motion controller can be connected to multiple computers through a hub.
PULL
PERIPHERAL I/F
(Ethernet)
(1) Hub connection settings
Before connection with a hub can be made, the Motion controller's settings must
be changed using a direct connection method.
(a) Connecting an Ethernet cable (Crossover cable)
Connect an Ethernet cable (Crossover cable) between the Motion controller
and a computer.
(b) Setting IP address of the Motion controller
Set the IP address located in the "Built-in Ethernet Port Setting" tab.
The default IP address value is [192.168.3.39]
Refer to (2)Note about IP address value setting.
No need to set "Subnet Mask Pattern" or "Default Router IP Address".
"Built-in Ethernet Port Setting"
(System Setting > Basic Setting > Built-in Ethernet Port Setting)
Ethernet cable
(straight cable)
Ethernet cable
(straight cable)
HUB
12 - 4
Computer
Panel
computer
Set IP address
Refer to (2) Note