12 COMMUNICATION
(b) Up to 16 different equipment can access the Motion controller.
(c) Hub
The hub can be either a 10BASE-T or 100BASE-TX port.
(It has to meet IEEE802.3 100BASE-TX or IEEE802.3 10BASE-T)
(d) The Ethernet cables must to be installed away from power cabling lines.
(e) The connections cannot be guaranteed under below conditions:
• Any connection made over the internet.
• Any connection made through a fire wall.
• Any connection made through a broadband router.
• Any connection made through a wireless LAN.
(f) When multiple Motion controllers are connected to MT Developer2, beware of
the below cautions:
• IP addresses must be different for each Motion controller.
• Different projects must be used for each Motion controllers on MT
Developer2.
• Only one instance each of the "Digital oscilloscope function" and "Test mode
function" can be used on a single computer at a time.
12 - 8