Factory setting Pt100 (DIN IEC)
Pickup offset
Damping
Certificates and approvals
Explosion protection ATEX and further approval authorities
ATEX PTB 05 ATEX 2049 X
Explosion protection FM for USA
FM 3024169C
Protection against explosion according to FM for Canada (cFMus)
FM 3024169
SITRANS TH100/TH320/TH420/TR320/TR420/TF320/TF420 with 4 to 20 mA/HART
Operating Instructions, 05/2020, A5E41864807-AB
Only the technical specifications listed in the certificates apply to applications in potentially explosive
atmospheres.
"Gas intrinsic safety" protec‐
tion type
"Non-sparking" protection
type
"Dust intrinsic safety" pro‐
tection type
Electrical data, operating conditions and installation instructions for operation in hazardous areas
can be found in the FM Certificate of Compliance as well as in the associated Control Drawing
A5E03638596A.
Electrical data, operating conditions and installation instructions for operation in hazardous areas
can be found in the FM Certificate of Compliance as well as in the associated Control Drawing
A5E03638596A.
In three-wire input
0 °C (0 °F)
0.0 s
II 1 G Ex ia IIC T6/T4 Ga
II (1) 2 G Ex ib [ia Ga] IIC T6/T4 Gb
II (1) 3 G Ex ic [ia Ga] IIC T6/T4 Gc
II 3 G Ex ic IIC T6/T4 Gc
II 3 G Ex nA IIC T6/T4 Gc
II 3 G Ex nA[ic] IIC T6/T4 Gc
II 1 D Ex ia IIIC T115°C Da
IS Cl I, II, III, Div 1, GP ABCDEFG T4/T5/T6
Cl I, ZN 0 AEx ia IIC T4/T5/T6
NI, S Cl I, II, III, Div 2, GP ABCDFG T4/T5/T6
NI IIC T4/T5/T6
IS Cl I, II, III, Div 1, GP ABCDEFG T4/T5/T6
Cl I, ZN 0 Ex ia IIC T4/T5/T6
NI, S Cl I, II, III, Div 2, GP ABCDFG T4/T5/T6
NI IIC T4/T5/T6
Technical data
12.1 SITRANS TH100
195