1 Alarms
Reactions:
Remedy:
Program Continuation:
300003
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
300004
Parameters:
Definitions:
Reactions:
1-464
- NC not ready.
- Channel not ready.
- NC Stop on alarm.
- NC Start disable in this channel.
- The NC switches to follow-up mode.
- Alarm display.
- Interface signals are set.
Please inform the authorized personnel/service department. Check MD 13010
DRIVE_LOGIC_NR for identical drive logic numbers and assign another number in the
range between 0 and 15 (0 corresponds to "No drive available" and is the only number
that may occur more than once in the MD array) to each drive.
Switch control OFF - ON.
Axis %1 drive %2 wrong module type %3
%1 = NC axis number
%2 = Drive number
%3 = Incorrect module type
The hardware configuration of the drive components established at the time of bus initial-
ization does not correspond to the information in machine data 13030
DRIVE_MODULE_TYPE[p]=... (p ... rack location index).
- NC not ready.
- Channel not ready.
- NC Stop on alarm.
- NC Start disable in this channel.
- The NC switches to follow-up mode.
- Alarm display.
- Interface signals are set.
Please inform the authorized personnel/service department. Enter MD 13030
DRIVE_MODULE_TYPE to match the drive modules that are plugged in.
Select MD 13010 DRIVE_LOGIC_NR and search for the drive logic number that is indi-
cated in the alarm text. The location index number + 1 results in the associated rack loca-
tion number. The VDD module belonging to this location is determined by the
configuration in MD 13030 DRIVE_MODULE_TYPE for the same location index.
Input value 1: 1-axis module, input value 2: 2-axis module.
Switch control OFF - ON.
Axis %1 drive %2 wrong drive type %3 (FDD/MSD)
%1 = NC axis number
%2 = Drive number
%3 = Drive type code
A feed module is inserted in the rack location determined by the drive logic number, but in
the corresponding NCK-specific MD 13040 DRIVE_TYPE, a main spindle is defined (or
vice versa).
- NC not ready.
- Channel not ready.
- NC Stop on alarm.
- NC Start disable in this channel.
- The NC switches to follow-up mode.
- Alarm display.
- Interface signals are set.
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Siemens AG, 2002. All rights reserved
11.02