1 Alarms
Remedy:
Program Continuation:
14048
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14050
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14051
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14060
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-164
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 wrong number of revolutions in circle programming
%1 = Channel number
%2 = Block number, label
In the circle programming, a negative number of full revolutions has been specified.
- Alarm display.
- Interface signals are set.
- Interpreter stop
- NC Start disable in this channel.
Modify part program.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 nesting depth for arithmetic operations exceeded
%1 = Channel number
%2 = Block number, label
For calculating arithmetic expressions in NC blocks, an operand stack with a fixed set size
is used. With very complex expressions, this stack can overflow.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Divide up complex arithmetic expressions into several simpler arithmetic blocks.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 arithmetic error in part program
%1 = Channel number
%2 = Block number, label
• In calculating an arithmetic expression, an overflow has occurred (e.g. division by zero)
• In a data type, the representable value range has been exceeded
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Analyze the program and correct the defective point in the program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 invalid skip level with differential block skip
%1 = Channel number
%2 = Block number, label
With "Differential block skip", a skip level greater than 7 has been specified. (In packet 1
specification of a value for the skip level is rejected by the converter as a syntax error, i.e.
the only possibility is a "Suppress block" ON/OFF on one level).
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Enter a skip level (number behind the slash) less than 8.
Clear alarm with NC START or RESET key and continue the program.