hit counter script

Siemens SINUMERIK 840D Series Diagnostics Manual page 239

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

11.02
16908
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16909
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16911
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16912
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16913
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Channel %1 action %2 only possible in reset state or at the block end
%1 = Channel number
%2 = Action number/action name
This action may only be performed in Reset state or at end of block.
- Alarm display.
Check the program status and channel status.
Clear alarm with the Delete key or NC START.
Channel %1 action %2 not allowed in current mode
%1 = Channel number
%2 = Action number/action name
You have to activate a different operating mode for the function to be activated.
- Alarm display.
Check operation and operating state.
Clear alarm with the Delete key or NC START.
Channel %1 mode change is not allowed
%1 = Channel number
The change from overstoring into another operating mode is not allowed.
- Alarm display.
After overstoring is terminated, it is possible to change to another operating state again.
Clear alarm with the Delete key or NC START.
Channel %1 program control: action %2 only possible in reset state
%1 = Channel number
%2 = Action number/action name
This action can only be performed in Reset state.
Example: Program selection through MMC or channel communication (INIT) can only be
performed in Reset state.
- Alarm display.
Reset or wait until processing is terminated.
Clear alarm with the Delete key or NC START.
Mode group %1 channel %2 mode change: action %3 not allowed
%1 = Channel number
%2 = Mode group number
%3 = Action number/action name
The change to the desired mode is not permitted. The change can only take place in the
Reset state.
Example: Program processing is halted in AUTO mode by NC Stop. Then there is a mode
change to JOG mode (program status interrupted). From this operating mode it is only
possible to change to AUTO mode and not to MDA mode!
- Alarm display.
Either activate the Reset key to reset program processing, or activate the mode in which
the program was being processed previously.
Clear alarm with the Delete key or NC START.
1 Alarms
1-239

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di seriesSinumerik 810d seriesSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840de ... Show all

Table of Contents

Save PDF