1 Alarms
Remedy:
Program Continuation:
60000
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61000
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61001
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61002
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-376
Wait until the axis has reached the end position or terminate the movement with delete
distance to go.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2:
%1 = Channel number
%2 = Block number, label
-
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
-
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 no tool compensation active
%1 = Channel number
%2 = Block number, label
Alarm triggered by following cycles: LONGHOLE, SLOT1, SLOT2, POCKET1 to
POCKET4, CYCLE71, CYCLE72, CYCLE90, CYCLE93 to CYCLE96.
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
- Interpreter stop
D-correction must be programmed before the cycle call.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 thread lead incorrect
%1 = Channel number
%2 = Block number, label
Alarm triggered by following cycles: CYCLE84, CYCLE840, CYCLE96, CYCLE97.
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
- Interpreter stop
Check parameter for the thread size or setting for the lead (contradict each other).
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 machining type wrongly defined
%1 = Channel number
%2 = Block number, label
The value of the VARI parameter for the machining has been incorrectly specified. Alarm
triggered by following cycles: SLOT1, SLOT2, POCKET1 to POCKET4, CYCLE71,
CYCLE72, CYCLE76, CYCLE77, CYCLE93, CYCLE95, CYCLE97, CYCLE98.
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
- Interpreter stop
Modify VARI parameter.
Clear alarm with the RESET key. Restart part program
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Siemens AG, 2002. All rights reserved