1 Alarms
61200
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61201
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61202
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61203
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-388
Channel %1 block %2 too many elements in the machining block
%1 = Channel number
%2 = Block number, label
Alarm triggered by following cycles: CYCLE76, CYCLE77.
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
- Interpreter stop
-
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 wrong sequence in the machining block
%1 = Channel number
%2 = Block number, label
The sequence of elements in the machining block is invalid. Alarm triggered by following
cycles: CYCLE108, E_CP_CE, E_CP_DR, E_MANAGE, F_CP_CE, F_CP_DR,
F_MANAGE.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Sort the sequence in the machining block.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 no technology cycle
%1 = Channel number
%2 = Block number, label
No technology cycle was programmed in the machining block. Alarm triggered by follow-
ing cycles: CYCLE108, E_MANAGE, F_MANAGE.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Program a technology block.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 no positioning cycle
%1 = Channel number
%2 = Block number, label
No positioning cycle was programmed in the machining block. Alarm triggered by follow-
ing cycles: CYCLE108, E_MANAGE, F_MANAGE.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Program positioning block.
Clear alarm with the RESET key. Restart part program
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Siemens AG, 2002. All rights reserved
11.02