1 Alarms
61223
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61224
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61225
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61226
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-392
Channel %1 block %2 approach path too short
%1 = Channel number
%2 = Block number, label
The approach path must not be less than zero. Alarm triggered by following cycles:
E_MI_CON, F_MI_CON.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Enter a greater value for the approach path.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 retract path too short
%1 = Channel number
%2 = Block number, label
The retract path must not be less than zero. Alarm triggered by following cycles:
E_MI_CON, F_MI_CON.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Enter a greater value for the retract path.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 swivel data block unknown
%1 = Channel number
%2 = Block number, label
An attempt was made to access a swivel data block which has not been defined.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Select another swivel data block or define a new swivel data block.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 swivel head cannot be exchanged
%1 = Channel number
%2 = Block number, label
The parameter "Swivel data block" is set to "No". In spite of this, an attempt has been
made to change the swivel head.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Set the parameter "Swivel data block" in the start-up screen form "Rotary axes" to "Auto-
matic" or "Manual".
Clear alarm with the RESET key. Restart part program
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition