hit counter script

Siemens SINUMERIK 840D Series Diagnostics Manual page 475

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

11.02
Program Continuation:
300411
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
300412
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
300413
Parameters:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
• 18270 $MM_NUM_SUBDIR_PER_DIR,
• 18310 $MM_NUM_DIR_IN_FILESYSTEM,
• Power On
• Reload saved data
• On error code 1 == 291: Replace the drive software and use version with suitable ACC
basic information.
• On error code 1 == 292: Replace the drive software and use fewer different versions of
the drive software.
Clear alarm with the RESET key. Restart part program
Axis %1 drive %2 error when reading a file (%3, %4)
%1 = NC axis number
%2 = Drive number
%3 = Error code 1
%4 = Error code 2
An attempt to read a data block, e.g. a drive boot file, from the file system has failed. The
data block or the file system is damaged.
- Alarm display.
- Interface signals are set.
If the error occurred during power-up, i.e. it is probably connected to a drive boot file,
delete all boot files and load them back into the control from the back-up copy.
Clear alarm with the RESET key. Restart part program
Error when storing a file (%1, %2)
%1 = Error code 1
%2 = Error code 2
An attempt to save a data block, i.e. the result of a measuring function, in the file system
has failed.
- Alarm display.
- Interface signals are set.
Please inform the authorized personnel/service department. Create more space in the file
system. It is normally sufficient to delete 2 NC programs or to free 4 - 8 Kbytes of memory.
If these remedies do not work, it will be necessary to increase the number of files per
directory or the size of the file system itself. To do so, proceed as follows:
• Save all data
• Change settings of machine data
• 18280 $MM_NUM_FILES_PER_DIR
• 18320 $MM_NUM_FILES_IN_FILESYSTEM
• 18350 $MM_USER_FILE_MEM_MINIMUM
• and, if necessary, of
• 18270 $MM_NUM_SUBDIR_PER_DIR
• 18310 $MM_NUM_DIR_IN_FILESYSTEM
• Power On
• Reload saved data
Clear alarm with the RESET key. Restart part program
Error when reading a file (%1, %2)
%1 = Error code 1
%2 = Error code 2
1 Alarms
1-475

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di seriesSinumerik 810d seriesSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840de ... Show all

Table of Contents

Save PDF