hit counter script

Siemens SIMATIC 427B-RTX Manual page 44

Microbox and panel pc
Table of Contents

Advertisement

User Tasks
2.3 Configuring the WinCC flexible Project
Changing the WinCC flexible runtime settings
To change the runtime settings for a new Windows user follow these steps:
1. Log on to the Panel PC with the new Windows user name and password.
2. Select the Start > Programs > Startup menu command to modify the RT Loader settings.
3. In the Directories section, change the locations for "Configuration file" and "Configuration
backup file" to D:\ drive locations, but do not modify the "Autostart application" location:
Figure 2-8
4. Click OK. Your runtime settings are now configured to persist after a reboot.
In addition, the default settings for recipes and archives also specify file locations on the C:\
drive. If you use these options, change these default settings to specify file locations on the
44
WinCC flexible 2007 RT Loader Settings
NOTICE
If you ever restore your Microbox 427B-HMI/RTX or Panel PC 477B-HMI/ -HMI/RTX
from a custom system image CD (Page 48) or from the Restore CD (Page 50) and
subsequently create a new Windows user, you must again change the runtime settings
to D:\ drive locations.
Microbox 427B-RTX/ -HMI/RTX and Panel PC 477B-HMI/ -HMI/RTX
Manual, 12/2007, A5E01217837-01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents