1 Alarms
Reactions:
Remedy:
Program Continuation:
12410
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12420
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-154
- Correction block
- Interface signals are set.
- Alarm display.
Press the NC Stop key and select the function "Correction block" with the softkey PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block.
Array initialization: Check the array index of the addressed element. The 1st array ele-
ment is given the index [0,0], the 2nd array element [0,1] etc. The right array index (col-
umn index) is incremented first.
In the 2nd row, the 4th element is also addressed with the index [1,3] (the indices start at
zero).
Array definition: Check the size of the array. The1st number indicates the number of ele-
ments in the 1st dimension (number of rows), the 2nd number indicates the number of
elements in the 2nd dimension (number of columns).
An array with 2 rows and 3 columns must be defined by specifying [2,3].
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 incorrect index type for %3
%1 = Channel number
%2 = Block number, label
%3 = Source string
In assigning a value to an element of an array variable, the array index was specified in a
way that is not allowed.
Only the following are allowed as array index (in square brackets):
• Axis identifier, provided the array variable was defined as data type FRAME.
• Integer values for all other data types.
- Correction block
- Interface signals are set.
- Alarm display.
Press the NC Stop key and select the function "Correction block" with the softkey PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block. Correct indices
of the array element with respect to variable definition or define the array variable differ-
ently.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 identifier %3 too long
%1 = Channel number
%2 = Block number, label
The symbol to be defined or the specified jump target has a name which is longer than the
32 characters allowed.
- Correction block
- Interface signals are set.
- Alarm display.
Press the NC Stop key and select the function "Correction block" with the softkey PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block. The symbol to
be created or the target of program jumps (label) must conform to the system specifica-
tions, that means the name must begin with 2 letters (but the 1st sign must not be "§") and
may be up to a maximum of 32 characters.
Clear alarm with NC START or RESET key and continue the program.
Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
10.04