1 Alarms
Remedy:
Program Continuation:
14660
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14700
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14701
Parameters:
Definitions:
Reactions:
1-218
Program the NCK input of the SETINT statement with a value of not less than 1 or greater
than 8.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 SETINT instruction with invalid priority
%1 = Channel number
%2 = Block number, label
The NCK input number must lie between 1 and 8. It is assigned a priority from 0 to 128 (1
is the highest priority) in the SETINT instruction with the keyword PRIO = ... .
Example:
If NCK input 5 changes to "1" the subroutine LIFT_Z should be started with the highest
priority.
N100 SETINT (5) PRIO = 1 LIFT_Z
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Program the priority of the NCK input with a value of not less than 1 or greater than 128.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 timeout during command to interpreter
%1 = Channel number
%2 = Block number, label
A timeout has occurred in control-internal commands such as ANWAHL (part program
selection), RESET (channel reset), REORG (reorganization of the preprocessing buffer)
and NEWCONFIG (change in the configuration-specific machine data = warm restart).
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department. If the runtime error occurred
as the result of a temporary excessive load on the system (e.g. in the MMC area or in
OEM application) error-free execution is possible on repeating the program or operator
action. Otherwise, the A&D MC system support should be contacted with a precise
description of the error situation:
(contact SIEMENS AG, System Support for A&D MC products, Hotline (Tel.: see alarm
1000)
Switch control OFF - ON.
Channel %1 block %2 number of available NC blocks reduced by %3
%1 = Channel number
%2 = Block number, label
%3 = Number of non-available blocks
After reset, it has been found that the number of available blocks has decreased com-
pared with the last reset. This is due to a system error. Part program execution can be
resumed after the alarm has been acknowledged. If the number of blocks no longer avail-
able is less than 28060 MM_IPO_BUFFER_SIZE, then the POWERON alarm 14700 is
output.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
10.04