hit counter script

Siemens SINUMERIK 840D Diagnostics Manual page 242

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

1 Alarms
Reactions:
Remedy:
Program Continuation:
15360
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
15370
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
15380
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
15390
Parameters:
Definitions:
1-242
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Check the part program, change the block search (typing error in the part program) and
restart the search.
Clear alarm with the RESET key. Restart part program.
Channel %1 illegal target of block search (syntax error)
%1 = Channel number
The specified search target (block number, label or string) is not allowed in block search.
- Alarm display.
Correct target of block search.
Clear alarm with the Delete key or NC START.
Channel %1 target of block search not found
%1 = Channel number
In a block search, an impermissible search target has been specified (e.g. negative block
number).
- Alarm display.
Check the specified block number, label or character string. Repeat entry with correct
search target.
Clear alarm with the Delete key or NC START.
Channel %1 block %2 illegal incremental programming in axis %3
%1 = Channel number
%2 = Block number, label
%3 = Axis
The first axis programming after "search to block end point" is performed incrementally.
This is not allowed in the following situations:
• After searching the target a transformation change has taken place.
• A frame with rotation component is active. The programmed axis is involved in the rota-
tion.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
• Find search destination in which the axes are programmed using an absolute reference.
• Deactivate adding of the accumulated search position with
$SC_TARGET_BLOCK_INCR_PROG = FALSE.
• Use search run with calculation "at contour".
Clear alarm with the RESET key. Restart part program.
Channel %1 block %2 %3 not executed during block search
%1 = Channel number
%2 = Block number, label
%3 = Source symbol
During block search, commands for switching, deleting and defining of the electronic gear
are not executed and not gathered but simply skipped.