1 Alarms
Reactions:
Remedy:
Program Continuation:
17010
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
17020
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-284
• Number of magazines: 18084 MM_NUM_MAGAZINE
• Number of magazine locations: 18086 MM_NUM_MAGAZINE_LOCATION
The following size is determined by software configuration: Number of magazine spacing
data blocks: P2 permits 32 such spacing data blocks.
Definition:
• 'Grinding data blocks': Grinding data can be defined for a tool from type 400 to 499.
Such a data block occupies additional memory, as it is planned for a cutting edge.
• 'Monitoring data blocks': Each cutting edge of a tool can be supplemented by monitoring
data.
• 'Magazine spacing data block': Spacings to other magazines can be defined for maga-
zine locations in internal magazines.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department.
• Modify machine data
• Modify the NC program, i.e. reduce the number of items related to the variable which
caused the error condition.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 no memory left
%1 = Channel number
%2 = Block number, label
When executing/reading files from the active working memory, it was found that there is
not enough memory space (e.g. for large multidimensional arrays or when creating tool
offset memory).
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department. Make arrays smaller or make
more memory space available for memory management of subroutine calls, tool offsets
and user variables (machine data MM_...).
See /FB/, S7 Memory Configuration
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 illegal array index 1
%1 = Channel number
%2 = Block number, label
A read or write access has been programmed to an array variable with invalid 1st array
index. The valid array indices must be contained within the defined array size and the
absolute limits (0 - 32 766).
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Correct the specification of array elements in the access instruction to match the defined
size. If an SPL is used in Safety Integrated, the field index via optional data may be sub-
ject to additional restrictions.
Clear alarm with NC START or RESET key and continue the program.