1-288
Channel %1 block %2 digital output no. %3 not activated
%1 = Channel number
%2 = Block number, label
%3 = No. of output
An attempt was made to read or set a digital NCK output (connector X 121) via the system
variable $A_OUT [n] with the index [n] greater than the specified upper limit in the NCK
machine data 10360 FASTIO_DIG_NUM_OUTPUTS.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Program index [n] of the system variable $A_OUT [n] only between 0 and the value in the
NCK machine data 10350 FASTIO_DIG_NUM_OUTPUTS.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 analog input no. %3 not activated
%1 = Channel number
%2 = Block number, label
%3 = Input number
An attempt has been made by means of the system variable $A_INA[n] to read an analog
input n that has not been activated by the MD 10300 FASTIO_ANA_NUM_INPUTS.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department. Modify part program or
machine data accordingly.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 analog output no. %3 not activated
%1 = Channel number
%2 = Block number, label
%3 = No. of output
An attempt has been made by means of the system variable $A_OUTA[n] to write or read
an analog output n that has not been activated by the MD 10310
FASTIO_ANA_NUM_OUTPUTS.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department. Modify part program or
machine data accordingly.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 NCK output %3 is assigned to a function via machine data
%1 = Channel number
%2 = Block number, label
%3 = No. of output
The programmed digital/analog output is assigned to an NC function (e.g. software
cams).
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.