10.04
Remedy:
Program Continuation:
18300
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
18310
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
18311
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
18312
Parameters:
Definitions:
Reactions:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Remove G code SUPA from the curve table definition. If possible, use G codes G53 or
G153 instead of SUPA.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 frame: fine shift not possible
%1 = Channel number
%2 = Block number, label
Allocation of a fine shift to settable frames or the basic frame is not possible since MD
$MN_FRAME_FINE_TRANS is not equal to 1.
- Interpreter stop
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department. Modify program or set MD
$MN_FRAME_FINE_TRANS to 1.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 frame: illegal rotation
%1 = Channel number
%2 = Block number, label
Rotations are not possible with NCU global frames.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Modify part program.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 frame: illegal instruction
%1 = Channel number
%2 = Block number, label
An attempt was made to read or write a frame which does not exist.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Modify part program.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 frame: fine shift not configured
%1 = Channel number
%2 = Block number, label
Fine shift must be configured with G58 and G59.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.