Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
- Alarm display.
Acknowledge alarm
Internal
Operator at the machine is waiting for support via remote diagnostics! %1 %2 %3
%4
%1 = IP address for existing Internet connection via modem
Will be triggered in "User Controlled" mode, if user explicitly selects and starts a host
object.
- Alarm display.
Acknowledge alarm
Internal
Operator at the machine is waiting for support via remote diagnostics! %1 %2 %3
%4
%1 = IP address for existing Internet connection via modem
Will be triggered in "User Controlled" mode, if user uses "Request Support" function.
- Alarm display.
Acknowledge alarm
Internal
Hardware drive bus: DCM not present
The DCM (Drive Communication Master, an ASIC on the NCU module that takes control
of the drive bus) has not signaled when powering up the drive. In the 840D, a hardware
fault is the possible cause of this error. (For the FM-NC, an incorrect configuration is also
possible via the NCK MD 13010 DRIVE_LOGIC_NR).
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department.
Exchange the NCU module.
Switch control OFF - ON.
Axis %1 drive number %2 not possible
%1 = NC axis number
%2 = Drive number
On powering up the drives, the NCK-specific machine data 13010 DRIVE_LOGIC_NR
was checked for impermissible inputs. In the MD, a drive logic number is entered that can
be selected as required within the established limits (drive number 0 = "No drive avail-
able"). Numbers greater than 15 are not allowed, nor may the same number be used
more than once. The MD array must be configured without spaces, i.e. as soon as the
logical drive number 0 is selected once, it is necessary for the logical drive number 0 to be
entered in all MDs with a higher location index [p].