10.04
Reactions:
Remedy:
Program Continuation:
300718
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
300719
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department.
For standard motors: Reset the drive (delete the bootfile) and repeat the startup. For
MSD, configure "1st motor" first.
For third-party motors: Enter a valid value in drive MD 1117: $MD_MOTOR_INERTIA
(motor moment of inertia).
Switch control OFF - ON.
Axis %1 drive %2 calculation dead time of current controller less than or equal to
zero
%1 = NC axis number
%2 = Drive number
The value in MD 1101: $MD_CTRLOUT_DELAY (dead time of current control circuit) is
less than or equal to zero. The dead time is calculated internally and automatically initial-
ized according to the type of module (1/2-axis, standard/performance module, 810D).
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Reset the drive (delete the
bootfile) and repeat the startup. Check drive MD 1101: $MD_CTRLOUT_DELAY (dead
time of current control circuit).
Switch control OFF - ON.
Axis %1 drive %2 motor not parameterized for delta operation
%1 = NC axis number
%2 = Drive number
On activating the star/delta switchover by drive MD 1013: $MD_ENABLE_STAR_DELTA,
the motor delta (motor 2) is not parameterized.
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Check and enter the
machine data for motor delta (motor 2).
Switch control OFF - ON.