1 Alarms
Remedy:
Program Continuation:
380072
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
380075
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
380500
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-648
Enter correct base addresses in the machine data:
• For length=1: Correct machine data MN_HW_ASSIGN_DIG_FASTOUT.
• For length=2: Correct machine data MN_HW_ASSIGN_ANA_FASTOUT.
• NCK restart
If the error cannot be eliminated by this procedure, please make a note of the error text
and contact the control system manufacturer.
Switch control OFF - ON.
Profibus DP: output slot for base address %1 (size %2) not allowed
%1 = Logical base address of the requested area
%2 = Size of the area in bytes
An incorrect logical base address was set for a digital or analog output, the area is resides
in the access range of the PLC (PIQ, base addresses < 128).
For length =1 it is a digital output,
For length =2 it is an analog output.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Only use addresses >= 128 for output slots.
Enter correct base addresses in the machine data:
• For length=1: Correct machine data MN_HW_ASSIGN_DIG_FASTOUT.
• For length=2: Correct machine data MN_HW_ASSIGN_ANA_FASTOUT.
• NCK restart
If the error cannot be eliminated by this procedure, please make a note of the error text
and contact the control system manufacturer.
Switch control OFF - ON.
PROFIBUS DP: DP I/O failure bus %2 slave %1
%1 = Slave address
%2 = Number of the affected bus
Failure of a PROFIBUS slot used by the NCK for digital or analog I/O.
- Alarm display.
Check that the PROFIBUS slave is operating correctly (all slaves must be included in the
bus, green LED).
Alarm display showing cause of alarm disappears. No further operator action necessary.
Profibus-DP: fault on drive %1, code %2, value %3, time %4
%1 = Axis
%2 = Fault code of drive (P824)
%3 = Fault value of drive (P826)
%4 = Fault time of drive (P948/P825)
Contents of fault memory of assigned drive.
- Alarm display.
See drive documentation for fault codes/fault values.
Alarm display showing cause of alarm disappears. No further operator action necessary.