03.04
No. 63
Explanation
Not allowed if
Remedy
No. 64
Explanation
Not allowed if
Remedy
No. 65
Explanation
Not allowed if
Remedy
No. 66
Explanation
Not allowed if
Remedy
No. 67
Explanation
Not allowed if
Remedy
No. 68
Explanation
Not allowed if
Remedy
No. 69
Explanation
Not allowed if
Remedy
No. 70
Explanation
Not allowed if
Remedy
No. 71
Explanation
Not allowed if
Remedy
Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Activate test run (VDI signal: Rapid traverse override).
1. The nesting depth is too great.
2. The active block, after which deceleration takes place, cannot be reorganized (occurs
when deceleration takes place over several blocks).
> Wait until the preceding ASUB is complete or abort the program.
> Abort the program.
Deactivate test run (VDI signal: Rapid traverse override).
1. The nesting depth is too great.
2. The active block, after which deceleration takes place, cannot be reorganized
(occurs when deceleration takes place over several blocks).
> Wait until the preceding ASUB is complete or abort the program.
> Abort the program.
Activate read-in disable for main-run block (VDI signal: Read-in disable).
-
-
Deactivate read-in disable for main-run block (VDI signal: Read-in disable).
-
-
Stop at end of block (alarm).
-
-
Stop all axes (alarm).
-
-
Activate program test (VDI signal: Program test).
1. Tool management is active.
2. The NCK channel is in a state other than "ready".
> Save tool data.
> Abort the program or process with the Reset key or wait for end of program.
Deactivate program test (VDI signal: Program test).
The NCK channel is in a state other than "ready".
> Abort the program or process with the Reset key or wait for end of program.
Stop at the end of block preparation (alarm).
-
-
1 Alarms
1-673