1 Alarms
10951
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10955
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10956
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10960
Parameters:
Definitions:
Reactions:
1-136
Channel %1 block %2 curve table %3: following value period is zero
%1 = Channel number
%2 = Block number, label
%3 = Number of curve table
--
- Alarm display.
Ensure that the table specification is correct.
Clear alarm with the Delete key or NC START.
Channel %1 block %2 curve table %3: missing master axis motion
%1 = Channel number
%2 = Block number, label
%3 = Number of curve table
A slave axis motion has been programmed without a master axis motion. This can also
occur if, with active radius compensation, a block is created in which the slave axis moves
but not the master axis. The alarm is for information only and can be suppressed by set-
ting MD $MC_CTAB_ENABLE_NO_LEADMOTION = 2.
- Alarm display.
Alarm can be switched off via MD $MC_CTAB_ENABLE_NO_LEADMOTION = 2.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 curve table %3: NC memory limit DRAM reached
%1 = Channel number
%2 = Block number, label
%3 = Number of curve table
Insufficient memory in the DRAM while defining the curve table.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Delete the curve tables that are no longer required in the DRAM or reconfigure the mem-
ory space for the curve tables. The curve table must then be redefined. Machine data for
memory configuration of the curve tables in DRAM:
MN_MM_NUM_CURVE_TABS_DRAM, MN_MM_NUM_CURVE_SEGMENTS_DRAM,
MN_MM_NUM_CURVE_POLYNOMS_DRAM.
Clear alarm with the RESET key. Restart part program.
Channel %1 block %2 COMPCURV/COMPCAD and radius compensation cannot be
used simultaneously
%1 = Channel number
%2 = Block number, label
Compressor types COMPCURV and COMPCAD cannot be used in combination with tool
radius compensation. Only compressor type COMPON can be activated while tool radius
compensation is active.
- Correction block is reorganized.
- Local alarm reaction.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm at block end.
Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
10.04