10.04
Remedy:
Program Continuation:
14082
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14085
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14088
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14090
Parameters:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Check NC part program for the following possible errors:
1. Check whether the target designation is identical with the label.
2. Is the jump direction correct?
3. Has the label been terminated with a colon?
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 label %3 program section not found
%1 = Channel number
%2 = Block number, label
%3 = Start or end label
The start point for repetition of the program part with CALL <program name> BLOCK
<start label> TO <end label> has not been found or the same program part repetition has
been called recursively.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Check the start and end labels for programming repetition in the user program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 instruction not allowed
%1 = Channel number
%2 = Block number, label
The instruction 'TML()' may only be used in the subprogram, which replaces the T com-
mand.
- Correction block is reorganized.
- Local alarm reaction.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm at block end.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 axis %3 doubtful position
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
An axis position larger than 3.40e+38 increments has been programmed. This alarm can
be suppressed with bit 11 in $MN_SUPPRESS_ALARM_MASK.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 invalid D number
%1 = Channel number
%2 = Block number, label