hit counter script

Siemens SINUMERIK 840D Diagnostics Manual page 184

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

1 Alarms
Definitions:
Reactions:
Remedy:
Program Continuation:
14091
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14092
Parameters:
Definitions:
Reactions:
1-184
A value less than zero has been programmed under address D.
A set of parameters with 25 correction values has been automatically assigned to each
active tool. Each tool can have 9 sets of parameters (D1 - D9, initial setting is D1). When
the D number changes, the new parameter set is active (D0 is used for deselecting the
correction values).
N10 G.. X... Y... T15 ; Parameter set D1 of T15 active
N50 G.. X... D3 M..
; Parameter set D3 of T15 active
N60 G.. X.. T20
; Parameter set D1 of T20 active
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Program D numbers in the permissible value range (D0, D1 to D9).
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 illegal function, index %3
%1 = Channel number
%2 = Block number, label
%3 = Index
A function was programmed which is not allowed in the current program context. The
code of the function in question is entered in "index":
Index == 1: "RET" command was programmed in the main program level
Index == 2: Conflict between "cancel level"/"clear number of passes" and "implicit GET"
Index == 3: ASUP conflict start immediately after selection of overstore (up to P3)
Index == 4: MD MN_G53_TOOLCORR = 1 : SUPA/G153/G53 programmed in G75
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Index == 1: Substitute "RET" command with M17/M30
Index == 2: Insert an auxiliary block (e.g. M99) after the subroutine call to which the "can-
cel level"/"clear number of passes" refers
Index == 3: Overstore an auxiliary block (e.g. M99), then start ASUP (up to P3)
Index == 4: With MD MN_G53_TOOLCORR = 1: Do not activate SUPA/G53/G153 in the
G75 block
Clear alarm with the RESET key. Restart part program.
Channel %1 block %2 axis %3 is wrong axis type
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
One of the following three programming errors has occurred:
1. The keyword WAITP(x) "Wait with block change until the specified positioning axis has
reached its end point" has been used for an axis that is not a positioning axis.
2. G74 "Reference point approach from the program" has been programmed for a spindle.
(Only axis addresses are permitted).
3. The keyword POS/POSA has been used for a spindle. (The keywords SPOS and
SPOSA must be programmed for the spindle positions).
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
10.04

Advertisement

Table of Contents
loading

Table of Contents