10.04
14768
Definitions:
Reactions:
Remedy:
Program Continuation:
14770
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14780
Parameters:
Definitions:
Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Axial auxiliary function for the NCU link cannot be output
Informational alarm for the part program developer.
An axial auxiliary function transmitted via an NCU link cannot be output as the transmis-
sion buffer for the
PLC is filled up to 100%.
- Alarm display.
- Warning display.
In the part program, cyclic data - in this case the output of auxiliary functions for link axes
on the interpolating NCU - should be separated with regard to the time.
Clear alarm with the Delete key or NC START.
Channel %1 block %2 auxiliary function programmed incorrectly
%1 = Channel number
%2 = Block number, label
The permissible number of programmed auxiliary functions per NC block has been
exceeded or more than one auxiliary function of the same auxiliary function group has
been programmed (M and S function).
In the user-defined auxiliary functions, the maximum number of auxiliary functions per
group in the NCK system settings has been defined for all auxiliary functions by means of
the machine data 11100 AUXFU_MAXNUM_GROUP_ASSIGN (default: 1)
For each user-defined auxiliary function to be assigned to a group, the assignment is
effected through 4 channel-specific machine data.
Return jump from asynchronous subprogram with M02/M17/M30, whereby the M code is
not alone in the block. This is impermissible if the asynchronous subprogram interrupts a
block with WAITE, WAITM or WAITMC. Remedy: Program M02/M17/M30 alone in the
block or replace via RET.
22010 AUXFU_ASSIGN_TYPE: type of auxiliary function, e.g. M
22000 AUXFU_ASSIGN_GROUP: required group
22020 AUXFU_ASSIGN_EXTENSION: any required extension
22030 AUXFU_ASSIGN_VALUE: function value
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Correct the part program - max. 16 auxiliary functions, max. 5 M functions per NC block,
max. 1 auxiliary function per group.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 unreleased option used (identification %3)
%1 = Channel number
%2 = Block number, label
%3 = Fine ID
A non-released option has been used in the block.
Brief identification description
1
LaserCtrl option
2
ClearCtrl option
3
FeedAdapt option
4
AaTOff option
5
Tang option
6
LeadCtab option
1 Alarms
1-227