1 Alarms
Reactions:
Remedy:
Program Continuation:
20101
Definitions:
Reactions:
Remedy:
Program Continuation:
20102
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
20103
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
20105
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-326
- Interface signals are set.
- Alarm display.
Please inform authorized personnel / the service department.
• Define three geometry axes for the digitizing channel by means of machine data.
• Use an interpolation cycle greater than 5ms.
Switch control OFF - ON.
Timeout during initialization of communication with the digitizer
The attempt to synchronize the communications link to the digitizing unit and to transfer
the machine parameters was aborted after the preset timeout limit of 15 seconds was
exceeded.
- Interface signals are set.
- Alarm display.
Check the connection to the digitizing unit (RS422 cable, supply voltage) and whether the
digitizing unit is switched on.
Clear alarm with the Delete key or NC START.
Channel %1: No or invalid trafo at digitizing active
%1 = Channel number
Prerequisite for the 3+2 axis digitizing is an active kinematic transformation. Permitted
transformations are the general 5-axis transformation and the universal inclinable head.
- Interface signals are set.
- Alarm display.
• Before digitizing, activate a permitted transformation.
• Select three-axis mode for digitizing via machine data.
Clear alarm with the Delete key or NC START.
Channel %1: Digitizing module does not support 3+2 axes digitizing
%1 = Channel number
Prerequisite for 3+2 axis digitizing is that the NCU and the digitizing module both have the
3+2 axis mode.
- Interface signals are set.
- Alarm display.
• SW update for the digitizing module.
• Select three-axis mode for the digitizing via machine data.
Clear alarm with the Delete key or NC START.
Channel %1: axes stopped by digitizer. Error code: %2
%1 = Channel number
%2 = Error code of digitizing unit
The digitizing unit has recognized an error in the communication and signaled this to the
NC.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Error code 1: Check cable
connection leading to the digitizing unit. Other error codes: See manual for digitizing unit.
Clear alarm with the RESET key. Restart part program
Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
10.04