1 Alarms
Remedy:
Program Continuation:
111109
Definitions:
Reactions:
Remedy:
Program Continuation:
111110
Definitions:
Reactions:
Remedy:
Program Continuation:
111111
Definitions:
Reactions:
Remedy:
Program Continuation:
111112
Definitions:
Reactions:
Remedy:
Program Continuation:
111115
Definitions:
Reactions:
Remedy:
Program Continuation:
111126
Definitions:
Reactions:
1-512
Spindle without attached encoder: Any NC language elements requiring the encoder sig-
nals must not be used.
Spindle with attached encoder: Enter the number of spindle encoders used in the MD
NUM_ENCS.
Clear alarm with the RESET key. Restart part program
Configured positioning velocity is too high
When referencing, the spindle turned through a greater distance than given in the axis-
specific machine data 34,060 REFP_MAX_MARKER_DIST, without receiving a reference
mark signal.
The check is performed for spindle positioning with SPOS or SPOSA when the spindle
has not previously run with speed control (S=...).
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Check and correct the MD 34 060 REFP_MAX_MARKER_DIST.
The value entered states the distance in [mm] or [degrees] between 2 zero markers.
Clear alarm with the RESET key. Restart part program
Velocity/speed is negative
The alarms 111110, 111115, 111126, 111127 and 111200 can occur at spindle start/stop.
- Alarm display.
Inform the service department. Please contact the responsible Siemens regional office.
Internal
Setpoint speed is zero
The programmed spindle speed setpoint is zero.
- Alarm display.
Set permissible spindle speed setpoint.
Internal
Invalid gear stage
An invalid gear stage was requested by the PLC.
- Alarm display.
Check the PLC program and axis-specific NC machine data.
Internal
Programmed position was not reached
The alarms 111110, 111115, 111126, 111127 and 111200 can occur at spindle start/stop.
- Alarm display.
Inform the service department. Please contact the responsible Siemens regional office.
Internal
Absolute value minus not possible
The alarms 111110, 111115, 111126, 111127 and 111200 can occur at spindel start/stop.
- Alarm display.
Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
10.04