hit counter script

Siemens SINUMERIK 840D Diagnostics Manual page 516

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

1 Alarms
Remedy:
Program Continuation:
111430
Definitions:
Reactions:
Remedy:
Program Continuation:
111900
Definitions:
Reactions:
Remedy:
Program Continuation:
111901
Definitions:
Reactions:
1-516
The following data must be checked:
Display MD's:
MD9004: $MM_DISPLAY_RESOLUTION
MD9600: $MM_CTM_SIMULATION_DEF_X
MD9601: $MM_CTM_SIMULATION_DEF_Y
MD9602: $MM_CTM_SIMULATION_DEF_VIS_AREA
MD9603: $MM_CTM_SIMULATION_MAX_X
MD9604: $MM_CTM_SIMULATION_MAX_Z
MD9605: $MM_CTM_SIMULATION_MAX_VIS_AREA
MD9616: $MM_CTM_TEACH_HANDW_FEED_P_MIN
MD9617: $MM_CTM_TEACH_HANDW_FEED_P_REV
MD9620: $MM_CTM_CYCLE_SAFETY_CLEARANCE
MD9633: $MM_CTM_INC_DEC_FEED_PER_MIN
MD9634: $MM_CTM_INC_DEC_FEED_PER_ROT
MD9637: $MM_CTM_MAX_INP_FEED_P_MIN
MD9638: $MM_CTM_MAX_INP_FEED_P_ROT
MD9639: $MM_CTM_MAX_TOOL_WEAR
MD9648: $MM_CTM_ROUGH_O_RELEASE_DIST
MD9649: $MM_CTM_ROUGH_I_RELEASE_DIST
MD10240: $MN_SCALING_SYSTEM_IS_METRIC
MD20150 [12]: $MC_GCODE_RESET_VALUES
Tool data: Length X, length Z, wear length radius X and Z, vconst.
Zero offsets: Position in X, Z.
Internal
Program not loaded. Error when converting old cycles in G code. No NC memory.
In previous ManualTurn versions, LINE, INCLINED and CIRCLE steps were saved as
cycles. Now these are saved as G codes (INCLINED, CIRCLE without angle program-
ming).
When loading a sequence, a check is run to see whether old cycles were used. If there
are old cycles, the sequence is converted and saved again in the NC. This alarm is output
if an error occurs thereby (memory full).
- Alarm display.
There must be enough memory for the original sequence and for the backup copy in order
for the sequence to be created.
Internal
Start only possible in basic display
A G code program can only be started from the basic display of an operating mode
(except MANUAL).
- Alarm display.
Switch to the basic display of an operating mode (except MANUAL). Start single step
mode with NC start.
Internal
Contour is contained in the current program, machining not enabled
There is a contour in the current Easystep sequence and it is not permitted to be
changed.
- Alarm display.
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
10.04

Advertisement

Table of Contents
loading

Table of Contents

Save PDF