Driving on/off of main circuit power supply with DC power supply [G] [A]
Use the magnetic contactor with an operation delay time (interval between current being applied to the coil until closure of
contacts) of 80 ms or less.
Servo amplifier
MR-J5-10_ to MR-J5-100_
MR-J5-200_/MR-J5-350_
MR-J5-500_
MR-J5-700_
MR-J5-60_4_ to MR-J5-200_4_
MR-J5-350_4_
Driving on/off of main circuit power supply with DC power supply [WG]
Use the magnetic contactor with an operation delay time (interval between current being applied to the coil until closure of
contacts) of 80 ms or less.
■MR-J5W2-_G_
Total output of rotary servo motors
300 W or less
From over 300 W to 600 W
From over 600 W to 1 kW
From over 1 kW to 2 kW
■MR-J5W3-_G_
Total output of rotary servo motors
450 W or less
From over 450 W to 800 W
From over 800 W to 1.5 kW
Magnetic contactor
SD-T12
SD-T21
SD-T35
SD-T50
SD-T12
SD-T21
Total continuous thrust of linear
servo motors
150 N or less
From over 150 N to 300 N
From over 300 N to 720 N
Total continuous thrust of linear
servo motors
150 N or less
From over 150 N to 300 N
From over 300 N to 450 N
6.10 Molded-case circuit breakers, fuses, magnetic contactors
Total output of direct drive motors
100 W or less
From over 100 W to 252 W
From over 252 W to 838 W
Total output of direct drive motors
252 W or less
From over 252 W to 378 W
6 OPTIONS AND PERIPHERAL EQUIPMENT
6
Magnetic
contactor
SD-T11
SD-T21
Magnetic
contactor
SD-T11
SD-T21
225