No.
Product name
Model
(7)
Battery cable
MR-BT6V1CBL_M
Cable length: 0.3 m,
1 m
(8)
Junction battery
MR-BT6V2CBL_M
cable
Cable length: 0.3 m,
1 m
(9)
Monitor cable
MR-J3CN6CBL1M
(10)
MR-ACN6CBL1M
(11)
Daisy chain power
MR-J5CNP12-J1
connector
MR-J5CNP12-J2
Description
(b)
(a)
(a) Housing: PAP-02V-O
Contact: SPHD-001G-P0.5 (JST)
(b) Connector: 10114-3000PE
Shell kit: 10314-52F0-008 (3M or equivalent)
(b)
(a)
(c)
(a) Housing: PAP-02V-O
Contact: SPHD-001G-P0.5 (JST)
(b) Housing: PALR-02VF-O
Contact: SPAL-001GU-P0.5 (JST)
(c) Housing: PAP-02V-O
Contact: SPHD-001G-P0.5 (JST)
3 (red)
2 (white)
1 (black)
CN6 connector
Housing: 51004-0300
Contact: 50011-8100
(Molex)
3 (red)
2 (white)
1 (black)
CN6 connector
Housing: SHR-03V-S
Contact: SSH-003T-P0.2-H (JST)
CNP1 connector
06JFAT-SAXGDK-KC7.5 (LA) (JST)
Applicable wire size:
2
2
0.8 mm
to 5.5 mm
(AWG 18 to 10)
Insulator OD: Up to 4.7 mm
CNP1 connector
06JFAT-SAXGFK-XLC (LA) (JST)
Applicable wire size:
2
2
1.25 mm
to 5.5 mm
(AWG 16 to 10)
Insulator OD: Up to 4.7 mm
CNP2 connector
05JFAT-SAXGDK-KC5.0 (LA) (JST)
Applicable wire size:
2
2
0.8 mm
to 2.1 mm
(AWG 18 to 14)
Insulator OD: Up to 3.9 mm
CNP2 connector
05JFAT-SAXGDK-HC5.0 (LA) (JST)
Applicable wire size:
2
2
0.8 mm
to 2.1 mm
(AWG 18 to 14)
Insulator OD: Up to 3.9 mm
6 OPTIONS AND PERIPHERAL EQUIPMENT
6.1 Cable/connector sets
Remark
For connection with
battery unit
Page 430
Battery
Page 430
Battery
For MR-J5W_-_G_
6
For MR-J5-_G_
For MR-J5-_A_
Used for connecting
the simple converter
when a 1-axis servo
amplifier of 1 kW or
less or a multi-axis
servo amplifier of
400 W or less is
used.
Page 192 MR-
CM simple converter
Used for connecting
the simple converter
when a 1-axis servo
amplifier of 2 kW or
less or a 2-axis servo
amplifier of 750 W or
more is used.
Page 192 MR-
CM simple converter
175