hit counter script

Mitsubishi Electric MELSERVO-J5 User Manual page 470

Ac servo system
Hide thumbs Also See for MELSERVO-J5:
Table of Contents

Advertisement

Symbol
Name
(i)
Z-phase pass status
(j)
Fully closed loop changing
device
(k)
Parameter Setting
(F/B pulse electronic gear)
(l)
Parameter Setting
(Dual F/B filter)
(m)
Parameter Setting
(Fully closed loop function)
[G] [WG]
Parameter Setting
(Fully closed loop function)
[A]
(n)
Parameter Setting
(Electronic gear)
[G] [WG]
Parameter Setting
(Electronic gear)
[A]
12 USING A FULLY CLOSED LOOP SYSTEM
468
12.5 Basic functions
Explanation
When the fully closed loop system is disabled, the Z-phase pass status of the servo motor encoder is
displayed.
When the fully closed loop system is enabled or when switching between semi closed loop control and
fully closed loop control is enabled, Z-phase pass status of the load-side encoder is displayed.
This item is displayed only when switching between semi closed loop control and fully closed loop
control is enabled.
The state of the semi closed loop control/fully closed loop control switching signal and the internal state
when switching between semi closed loop control and fully closed loop control is enabled.
With this servo parameter, the feedback pulse electronic gears ([Pr. PE04 Fully closed loop control -
Feedback pulse electronic gear 1 - Numerator] and [Pr. PE05 Fully closed loop control - Feedback pulse
electronic gear 1 - Denominator]) for servo motor encoder pulses can be displayed and set.
Page 458 Setting the feedback pulse electronic gear
With this servo parameter, the band for [Pr. PE08 Fully closed loop dual feedback filter] can be
displayed and set.
The servo parameters for the fully closed loop control can be displayed and set.
Click "Parameter Setting" to display the "Parameter Setting (Function display (List))" window.
The servo parameters for the fully closed loop control can be displayed and set.
Click "Parameter Setting" to display the "Parameter Setting (Function display (List))" window.
Set the servo parameters for the electronic gears.
[Pr. PA06 Electronic gear - Numerator], [Pr. PA07 Electronic gear - Denominator]
Set the servo parameters for the electronic gears.
[Pr. PA05 Number of command input pulses per revolution], [Pr. PA06 Electronic gear - Numerator], [Pr.
PA07 Electronic gear - Denominator], [Pr. PA21.3 Electronic gear compatibility selection]
Unit

Advertisement

Table of Contents
loading