Direct Drive Motor Specifications and Instruction Manual
2 Specifications
[ TM-RBP500J20 ]
Power supply lead : 3-AWG6 (Finish outer diameter
(U, V, W)
Thermistor lead : 2-AWG18 (Finish outer diameter
(MT1, MT2)
Ground lead : 1-AWG6 (Finish outer diameter
Lead-out range
Recommended inlet/outlet
of lead wire
position for cooling liquid
12-M8 screw
Depth 18
(Note 1) Do not move the stator by holding the lead wire.
(Note 2) Degree of protection is IP00. Use explosion-proof oil, etc., as necessary.
(Note 3) Continuous rated torque is assured only when the required cooling capacity is satisfied.
(Note 4) There is no problem on the functionality or performance even if the molded parts include sink marks or voids, etc.
[ TM-RBS500J20 ]
(Note 1) Deliverable rotors are magnetized. Please note the magnetic attraction.
(Note 2) Take special care for the magnet part not to hit against a thing (A crack or chip may occur).
(Note 3) Degree of protection is IP00. Use explosion-proof oil, etc., as necessary.
(Note 4) There is no problem on the functionality or performance even if the molded parts include sink marks or voids, etc.
6.7)
∅
2.3)
∅
Effective length
7.04)
∅
300
191
Recommended inlet/outlet
position for cooling liquid
(250)
38
(Wire mark position)
28
(135: Cooling groove)
Wire mark
MT1
MT2
U
V
W
(1.5)
Rotor
(TM-RBS500J20)
12-M8 screw
Depth 18
38
28
1.5
A
25.7
(28)
188
25
4
19
[Unit:mm]
12-M8 screw
Depth 18
1
Detail A
[Unit:mm]
12-M8 screw
Depth 18
IB-1501068-C