hit counter script

Outputs; Construction; Operating Conditions - Siemens SITRANS LU150 Operating Instructions Manual

Ultrasonic transmitters
Table of Contents

Advertisement

Technical data

8.4 Outputs

8.4
Outputs
mA output
Range
Span
Accuracy
Resolution
Loading
Cable
8.5

Construction

Combined sensor and electronics package
Sensor housing
material
mounting
optional flange
adapter
Enclosure material
PBT
Connection
Enclosure rating
Type 6/NEMA 6/IP68 (2 meters for 24 hours)
Weight
1.3 kg
8.6

Operating conditions

Location
indoor / outdoor
Ambient temperature
continuous
-30 to +60 °C (-22 to +140 °F)
-20 °C (-5 °F) if metal mounting
Relative humidity
suitable for outdoor (Type 6/NEMA 6/IP68 (2 meters for 24 hours))
Installation category
I
Pollution degree
4
36
4 to 20 mA
proportional or inversely proportional
0.25% of full scale at reference conditions
3 mm (0.125")
600 ohms max loop load at 24 V DC supply
twisted pair, AWG 28 to 16 (0.34 to 1.5 mm) or equivalent
PVDF
threaded
1 x M20 or 1/2" NPT conduit entry
2 screw terminal block for 2.5 mm
(14 ga) solid wire / 1.5 mm
2
2" NPT ((Taper), ANSI/ASME B1.20.1)
R 2" ((BSPT), EN 10226)
G 2" ((BSPP), EN ISO 228-1
4" Sanitary
2" NPT - 7ML1830-1BT
2" BSPT - 7ML1830-1BU
2
(16 ga) stranded wire max
Operating Instructions, 03/2016, A5E34590123-AB