Parameter individual write
This program writes parameters to the input ASLINKER with bit address 0.
The parameters to be written to the slave module are as follows.
*1
Item
Device parameter 1 (disconnection monitoring function setting)
Device parameter 2 (disconnection detection enabled CH setting)
*1 For details on the parameters, refer to the manual for the slave module used.
■Device to use
Device
X1000
X1011
Y1010
W1000
W1002
W1500
W1501
D200 to D211
D300 to D308
D400
F1
F2
F3
F4
F5
M0
M1
M2
M10
M11
M50
M51
M52
M53
SD63
SB49
8 PROGRAMMING
104
8.2 Program Example
Description
Remote READY
Parameter access completion flag
Slave module parameter access request command
Latest error code storage area
Latest alarm code storage area
Parameter access specification
Parameter access target module ID specification
Control data used with the SLMPSND instruction
• D200: Execution/error completion type
• D201: Completion status
• D202: Channel used by own station
• D203: IP address of external device (third and fourth octets)
• D204: IP address of external device (first and second octets)
• D205: Destination port number
• D206: Request destination network number
• D207: Request destination station number
• D208: Request destination module I/O number
• D209: Request destination multidrop station number
• D210: Number of resends
• D211: Arrival monitoring time
Request data (write) used with the SLMPSND instruction
• D300: Request data length
• D301: Monitoring timer
• D302: Command
• D303: Subcommand
• D304: Start address (lower 16 bits)
• D305: Start address (upper 16 bits)
• D306: Word length
• D307: Write data (device parameter 1)
• D308: Write data (device parameter 2)
Response data (write) used with the SLMPSND instruction
• D400: Response data start device
SLMPSND instruction (write) completed with an error
Parameter access target module ID error
Parameter setting value error
Parameter access error
Other errors
SLMPSND instruction (write) completed
SLMPSND instruction (write) completed (error)
Parameter write for slave module completed successfully
Parameter reflection request (read)
Parameter reflection request (write)
Read start contact
Write start contact
Parameter read for slave module completion flag
SLMPSND instruction (write) successful completion flag
Number of annunciators
Data link status of own station (of master station)
Setting value
2 (monitor only the signal side)
1 (IN0 only)