hit counter script

Mitsubishi Electric AnyWire ASLINK User Manual page 170

Programmable controller
Table of Contents

Advertisement

Operation example
The operation examples of the double verification setting of bit data are as follows. (The value indicates the address.)
■All points, double verification of a bit
(1)
0
1
...
bit bit bit bit bit
(2)
(1) Transmission cycle
(2) Perform double verification in 1-bit unit.
■Double verification in 16-bit (1 word) units until the 1st word
0
word
(2)
(1) Transmission cycle
(2) Perform double verification in 16-bit (word) units until the 1st word.
(3) Perform double verification in 1-bit unit after the 16th bit (one word + one bit).
■Double verification in 16-bit (1 word) units until the 2nd word
0
word
(1) Transmission cycle
(2) Perform double verification in 16-bit (word) units until the 2nd word.
(3) Perform double verification in 1-bit unit after the 32nd bit (two words + one bit).
■Double verification in 16-bit (1 word) units until the 16th word
0
word
(1) Transmission cycle
(2) Perform double verification in 16-bit (word) units until the 16th word.
APPX
168
Appendix 4 Double Verification
bit bit
(1)
15 16
...
bit
bit
bit
bit
(3)
(1)
word
(2)
(1)
word
(2)
31 32
...
bit
bit
bit
bit
(3)
...
word
255

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nz2aw1gnal

Table of Contents