2. SPECIFICATION
Diesel fuelled infrared heater for indoor (well ventilated) and outdoor applications. Combustion gases are catalysed so the heater requires no flue
or exhaust pipe. Integral fuel tank and large wheels make the unit fully manoeuvrable. Tank capacity is 51 litres, giving approx. 14 hours operation
per full tank. Stainless steel combustion chamber may be adjusted, in the vertical plane, through 40° to direct heat as required.
Output:
38.3kW
Power Supply:
230V 50Hz 185W
Fuel/Fuel consumption: Diesel Oil / 3.0kg/hr
Tank capacity:
51ltr
Min/Max. Height:
915 / 1115mm
Width:
640mm
Length:
955mm
Weight:
98kg
3. INSTALLATION
Follow the safety instructions outlined in section 1
3.1
Fill the fuel tank with clean, water-free diesel.
3.2
Connect to a 230V 50Hz earthed electrical outlet (in compliance with local
regulations).
3.3
At extremely low temperatures, ignition may prove difficult. Check the
tank, connections and filter for paraffin formation and mix the diesel oil
with 10% kerosene.
3.4
To direct the infrared radiation, loosen the clamping levers on both sides,
position the radiating cone as required and tighten the clamping levers.
4. OPERATION
4.1
To start, set the switch to ON
4.2
To stop, set the switch to OFF
4.3
Ignition does not take place immediately but after a preheating procedure followed by a pre-purge time of around 30 seconds. Should no fuel
flow to the burner within 4 seconds, the heater switches automatically to lock-out mode. In this event, check and eliminate the possible
causes of lock-out (see section 6) then press the RESET button to restart the heater. Should the heater remain inoperative, check that the front
radiator is not directly exposed to intense lights (sunlight, lamps etc) as this might interfere with the operation of the burner control unit.
5. MAINTENANCE
5.1
Switch off, unplug and allow the heater to cool and close diesel shut-off valve before performing any form of maintenance.
5.2
Ensure that the unit is checked and the burner calibrated by a qualified person at least once a year.
5.3
General Maintenance
5.3.1 Replace the fuel filter cartridge at least every 200-300 operating hours, but sooner if you see water or dirt particles in the filter glass.
5.3.2 Should fuel remain unused in the tank for an extended period of time and become contaminated with dirt and/or water, empty the tank
and refill with clean diesel.
6. TROUBLE SHOOTING
Malfunction
The heater does not start, when the switch is
set to ON
The heater starts but a malfunction immediately
occurs
The heater operates but the combustion is
smoky
The burner fan continues to run even though
the heater has been switched off and cooled
down
Declaration of Conformity
INFRARED DIESEL HEATER 38kW
Model: IR40
Machinery Directive 98/37/CE
Low Voltage Directive 73/23/CEE
EMC Directive 89/336/CEE
CE Marking Directive 93/68/EEC
NOTE:
It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our catalogue and latest promotions call us on 01284 757525 and leave your full name, address and postcode.
a) no electrical supply
b) defective ON/OFF switch
c)
burner lock-out
d) defective motor/capacitor
a) no diesel in the tank
b) air in the fuel circuit
c) diesel filter clogged
d) diesel burner lock-out
a) blocked nozzle
b) filter is clogged
c)
water in the fuel
d) paraffin formation in the main filter
e) not enough fuel in the tank
f ) air suction in the oil line
g) defective solenoid valve
a) defective post-ventilation relay
We, the sole importer into the UK, declare that the products listed below are in conformity with the following EEC standards and directives
The construction file for these products are held by the Manufacturer and may be inspected, by a national
authority, upon request to Jack Sealey Ltd.
Signed by Mark Sweetman
Sole UK Distributor
Sealey Group,
Bury St. Edmunds, Suffolk.
Possible causes
01284 757500
01284 703534
Remedy
a) check mains, switch and fuses
b) replace ON/OFF switch
c) reset diesel burner. If lockout repeats
immediately, leave 4-5 mins and reset again.
d) check motor/capacitor, replace if necessary .
a) refill tank with diesel
b) check diesel circuit connections
c) replace filter cartridge
d) see operating instructions for burner.
a) replace nozzle
b) clean filter
c) fill tank with clean diesel
d) replace diesel preheater
e) fill tank completely
f ) tighten connections in the diesel circuit
g) see operating instructions for burner
a) replace post-ventilation relay
28th April 2006
www.sealey.co.uk
Web
sales@sealey.co.uk
email
For Jack Sealey Ltd.
Sole importer into the UK
of Sealey Power Products
IR40 - 1 - 280406