5 CONNECTING WEB SERVER MODULE TO NETWORK

5.1.2 Access procedure when obtaining IP address from DHCP server

GX Developer
IP address, subnet mask:
Automatically obtained from DHCP server
Mount the Web server module to slot "0" of the base
unit and power the programmable controller ON.
Connect the Web server module to the personal
computer with a crossing cable.
On the following screens from the Administrative menu,
make network setting of the Web server module.
System setting
Account setting
E-mail setting
Address notification setting
Power the programmable controller OFF and connect
the Web server module to LAN.
Power the programmable controller ON.
The Web server module is automatically linked to the
network at start-up.
Using address notification obtain the Web server
module's address.
Start a Web browser on the computer and access the
Web server module.
Monitor device data on the "Device monitor" screen.
5 - 4
The following shows the procedure for access from the external device to the
programmable controller CPU when an IP address for the Web server module is
obtained from the DHCP server.
[System configuration for LAN connection]
IP address, subnet mask:
Automatically obtained from DHCP server
Personal computer
Start
Completed
Web server module
For PC's network setting for one-to-one connection, refer
to Section 4.5.
(1) Network setting of Web server module
For LAN connection, refer to Section 4.4.1.
(2) Network connection of Web server module
(3) Receiving the account notification by personal computer
(4) Access to Web server module
For device monitor, refer to Section 6.2.1.
MELSEC-Q
DHCP server
Ethernet
Mail server
(SMTP, POP3)
5 - 4